We offer a full range of fire protection services tailored to your needs

Fire detection and alarm faults demand immediate attention.
Faulty equipment, unresolved isolations, and outstanding deficiencies compromise building safety, threaten compliance, and expose owners to significant liability.

Applied Fire Technology’s Dry Fire Division combines qualified fire technicians and licensed electricians to deliver seamless fault diagnosis, repairs, and system restoration efficiently.

Every fault is documented, every isolation tracked, and every rectification recorded to maintain compliance and keep your fire protection systems operational.

Fire Indicator System Fault-Finding & Specialist Rectification

Our experienced fire detection technicians provide advanced fault diagnosis and rectification across all fire detection system components, including detectors, modules, loop infrastructure, network communications, and field wiring. Leveraging extensive technical expertise and systematic fault-finding methodologies, we identify and resolve both persistent and intermittent faults, including complex issues that cannot be readily reproduced during attendance.

Using detailed diagnostic analysis, trend monitoring, and historical system data, we isolate root causes rather than address symptoms, reducing repeat faults and improving overall system reliability. We comprehensively document all findings, corrective actions, and recommendations against the relevant asset in our maintenance platform, ensuring a complete fault history remains attached to the building for future reference, compliance verification, and lifecycle management.

Our approach minimises disruption, restores system integrity quickly, and gives clients confidence that their fire detection systems remain compliant, operational, and fully capable of protecting occupants and assets.

Specialist diagnosis, repair, and reconfiguration of Fire Indicator Panels (FIPs), including fault rectification, electronic board replacement, firmware updates, cause-and-effect programming, monitoring interface faults, and communication failures.

Our technicians restore system integrity by ensuring the panel accurately reflects the building’s current fire protection infrastructure and operational requirements. Where discrepancies between the programmed configuration and the physical installation are identified, they are thoroughly investigated, documented, and reported with remediation recommendations, ensuring compliance, reliability, and complete transparency rather than relying on temporary workarounds.

Expert fault diagnosis, repair and optimisation of Emergency Warning and Intercommunication Systems (EWIS), including amplifiers, speaker circuits, wardens’ intercommunication points (WIPs), microphones, control equipment, and evacuation zoning.

Our technicians systematically identify and rectify faults affecting system performance, reliability, and code compliance, restoring confidence that occupants will receive clear and effective emergency communications when it matters most.

We validate repairs through comprehensive post-repair testing, including audibility, intelligibility, and zoning verification, to confirm the system performs as intended throughout the building. A warning system that merely passes a functional test is not enough. We ensure it delivers clear, intelligible instructions to building occupants during an emergency, so you can be confident the system will perform when lives depend on it.

Professional replacement, testing and rectification of residential smoke alarms within common areas and sole occupancy units, in accordance with AS 3786 and applicable legislative requirements. Our technicians assess alarm condition, coverage, positioning and functionality, ensuring defective, non-compliant or end-of-life devices are replaced with fit-for-purpose equipment.

We manage access requirements proactively by coordinating with residents, tenants, property managers, and managing agents, ensuring visits are planned and productive rather than relying on unsuccessful access attempts. Every inspection, replacement and test result is recorded, providing a clear compliance history and giving property owners confidence that life safety obligations are being effectively managed across their portfolio.

Rectification of emergency and exit lighting defects, including failed fittings, charging system faults, battery failures and luminaires that illuminate under normal conditions but do not achieve their required emergency discharge duration. Following repair or component replacement, the fitting is retested to verify compliance with the required 90-minute emergency operation period. All defects, corrective actions and test results are recorded against the relevant asset, providing a complete maintenance and compliance history for the building.

Management of system isolations from the moment they are applied through to verified restoration, ensuring the building’s responsible person is notified of both the isolation and its return to service. Every isolation is recorded, monitored and tracked within the maintenance platform, providing a clear audit trail and reducing the risk of critical protection systems remaining inadvertently disabled.

An unrestored isolation represents a live risk exposure that may remain undetected until the next scheduled service visit, making disciplined isolation management essential to maintaining system integrity, compliance and occupant safety.

Completion of defect rectification works with all actions, repairs and outcomes recorded directly into the compliance management system. This closes the loop between the original inspection or service report that identified the defect and the corrective works undertaken, providing a complete audit trail.

The updated compliance record confirms the defect has been resolved, supports regulatory compliance requirements, and ensures building owners have accurate, traceable documentation of both the issue and its resolution.